Skip to content Skip to navigation

4 inch wafer

Short Name: 
4"

The following is a list of equipment where 4 inch round substrates are allowed.

Subscribe to
Equipment name & NEMO ID Training Required & Charges Cleanliness Locationsort descending Notes
SEM -Zeiss Merlin
sem-merlin
SEM-Merlin Training "All" SNF Exfab Paul G Allen 104 Stinson
Profilometer AlphaStep D-300
alphastep2
AlphaStep2 Training Flexible SNF Exfab Paul G Allen 104 Stinson
Headway 3 Manual Resist Spinner
headway3
Resist Coat (manual) Headway 3 Training "All" SNF Exfab Paul G Allen 104 Stinson
Ex Fab Develop Wet Bench
wbexfab_dev
WbExfab_Dev Training Flexible SNF Exfab Paul G Allen 104 Stinson

Manual development of resist in beakers. SNF approved developers only. No solvents!

Ex Fab Solvent Wet Bench
wbexfab_solv
WbExfab_Solv Training Flexible SNF Exfab Paul G Allen 104 Stinson
Finetech Lambda
flipchipbonder
Flip Chip Bonder Training Flexible SNF Exfab Paul G Allen 104 Stinson
Keyence Digital Microscope VHX-6000
keyence
Microscope Keyence Training "All" SNF Exfab Paul G Allen 104 Stinson
Nanospec 210XP
nanospec2
Nanospec Training "All" SNF Exfab Paul G Allen 104 Stinson

Manual Film Thickness Measurement. Single or dual layer transparent films > 300 Å

Heidelberg MLA 150
heidelberg
Heidelberg Training "All" SNF Exfab Paul G Allen 104 Stinson

Direct Write

Profilometer Alphastep 500
alphastep
Alphastep 500 Profilometer Training Flexible SNF Exfab Paul G Allen 104 Stinson

500Å to 300µm

PlasmaTherm Shuttlelock PECVD System
ccp-dep
PlasmaTherm Shuttlelock PECVD System Training "All" SNF Paul G Allen L107 Cleanroom

To maintain cleanliness level, cleans of both the chamber and wafers are required prior to processing -

Substrates in clean category: Pre-Diffusion Clean

For semi-clean substrates: Standard Metal Clean (SRS100 + PRS1000) . Run Chamber clean (no dummies) and conditioning with clean dummies prior to run

Wet Bench Flexible Solvents
wbflexsolv
Wet Bench Flexible Solvents 1 and 2 Training Flexible SNF Paul G Allen L107 Cleanroom

Manual solvent cleaning of substrates or resist removal.

SPTS uetch vapor etch
uetch
SPTS uetch vapor etch Training "All" SNF Paul G Allen L107 Cleanroom

Pieces need a carrier wafer; Isotropic Etching

Flexus 2320 Stress Tester
stresstest
Stress Tester Flexus 2320 Training "All" SNF Paul G Allen L107 Cleanroom
AJA2 Evaporator
aja2-evap
Evaporator AJA2 Training Flexible SNF Paul G Allen L107 Cleanroom

For more than 300nm deposition, please contact Gabe Catalano <gcatalano@stanford.edu> in advance

CHA Solutions II Evaporator
cha-evap
Evaporator CHA Training Flexible SNF Paul G Allen L107 Cleanroom

For more than 300nm deposition, please contact Neel Mehta <nmehta26@stanford.edu> in advance

PlasmaTherm Versaline HDP CVD System
hdpcvd
PlasmaTherm Versaline HDP CVD System Training "All" SNF Paul G Allen L107 Cleanroom

To maintain cleanliness level there are cleans required for both the chamber and wafers prior to processing -

Substrates in clean category: Pre-Diffusion Clean

For semi-clean substrates: Standard Metal Clean (SRS100 + PRS1000) .  Run Chamber clean (no dummies) and conditioning with clean dummies prior to run

Critical Point Dryer Tousimis Automegasamdri-936
cpd
Critical Point Dryer Training Flexible SNF Paul G Allen L107 Cleanroom

CO2 drying after release of micromachined devices

HMDS Vapor Prime Oven, YES
yes
YES Prime Oven Training "All" SNF Paul G Allen L107 Cleanroom

Two programs: Singe and HMDS prime or Singe only. No Resist allowed!

Wet Bench Clean_res- hotphos
wbclean_res-hotphos
Wet Bench Clean Piranha/HF/Phosphoric Training Clean SNF Paul G Allen L107 Cleanroom

Resist should have been removed

Pages

Equipment name & NEMO ID Technique Cleaning Required Cleanliness Primary Materials Etched Other Materials Etched Material Thickness Range Materials Lab Supplied Minimum Resolution Exposure Wavelength Mask Size Resist Developer Process Temperature Range Chemicals Gases Substrate Size Substrate Type Maximum Load
Aixtron Black Magic graphene CVD furnace
aixtron-graphene
Flexible
800 °C - 1100 °C
,
1x4" wafer or Copper/Nickel foil
Aixtron MOCVD - III-N system
aix-ccs
Clean (MOCVD)
0.00 - 5.00 μm
400 °C - 1300 °C
,
,
,
4"x1, 2"X3, pieces
Aixtron MOCVD - III-V system
aix200
Pre-Diffusion Clean Flexible
0.00 - 5.00 μm
300 °C - 800 °C
,
,
,
,
,
4"x1 wafer or 2"x1 wafer or 4 pieces
AJA Evaporator
aja-evap
Flexible
0.00 - 300.00 nm
,
,
,
,
,
,
,
,
,
,
,
4"x3 or 6"x1 wafers or pieces
AJA2 Evaporator
aja2-evap
Flexible
0.00 - 300.00 nm
,
,
,
,
,
4"x3 or 6"x1 wafers or pieces
AMAT Centurion Epitaxial System
epi2
Pre-Diffusion Clean Clean
50.00 Å - 3.00 μm
600 °C - 1200 °C
1
ASML PAS 5500/60 i-line Stepper
asml
"All"
365 nm 5 inch
,
,
,
,
CHA Solutions II Evaporator
cha-evap
Flexible
0.00 - 300.00 nm
,
,
,
,
,
4"x15 or 6"x3 wafers or pieces
Critical Point Dryer Tousimis Automegasamdri-936
cpd
Flexible
,
,
,
,
,
,
,
,
,
DISCO Wafer Saw
DISCO wafersaw
Flexible ,
,
,
,
,
,
,
1x4", 1x6" or 1x8" wafer, or pieces
EVG 101 Spray Coater
evgspraycoat
"All" ,
,
,
,
1
Ex Fab Develop Wet Bench
wbexfab_dev
Flexible
Ex Fab Solvent Wet Bench
wbexfab_solv
Flexible
Fiji 1 ALD
fiji1
Semiclean
1.00 Å - 50.00 nm
24 °C - 350 °C
,
,
Fiji 2 ALD
fiji2
Flexible
1.00 Å - 50.00 nm
24 °C - 350 °C
,
,
,
,
,
,
,
,
,
,
,
,
Fiji 3 ALD
fiji3
Flexible
1.00 Å - 50.00 nm
24 °C - 350 °C
,
,
Finetech Lambda
flipchipbonder
Flexible
°C - 400 °C
,
,
,
,
,
1
First Nano carbon nanotube CVD furnace
cvd-nanotube
Flexible
800 °C - 1100 °C
,
1x4" wafer or multiple pieces
Flexus 2320 Stress Tester
stresstest
"All" ,
,
,
,
,
,
,
,
1
Gasonics Aura Asher
gasonics
Clean, Semiclean
25