SEM -Zeiss Merlin sem-merlin |
SEM-Merlin Training |
"All" |
SNF Exfab Paul G Allen 104 Stinson |
|
Profilometer AlphaStep D-300 alphastep2 |
AlphaStep2 Training |
Flexible |
SNF Exfab Paul G Allen 104 Stinson |
|
Headway 3 Manual Resist Spinner headway3 |
Resist Coat (manual) Headway 3 Training |
"All" |
SNF Exfab Paul G Allen 104 Stinson |
|
Ex Fab Develop Wet Bench wbexfab_dev |
WbExfab_Dev Training |
Flexible |
SNF Exfab Paul G Allen 104 Stinson |
Manual development of resist in beakers. SNF approved developers only. No solvents! |
Ex Fab Solvent Wet Bench wbexfab_solv |
WbExfab_Solv Training |
Flexible |
SNF Exfab Paul G Allen 104 Stinson |
|
Finetech Lambda flipchipbonder |
Flip Chip Bonder Training |
Flexible |
SNF Exfab Paul G Allen 104 Stinson |
|
Keyence Digital Microscope VHX-6000 keyence |
Microscope Keyence Training |
"All" |
SNF Exfab Paul G Allen 104 Stinson |
|
Nanospec 210XP nanospec2 |
Nanospec Training |
"All" |
SNF Exfab Paul G Allen 104 Stinson |
Manual Film Thickness Measurement. Single or dual layer transparent films > 300 Ã
|
Heidelberg MLA 150 heidelberg |
Heidelberg Training |
"All" |
SNF Exfab Paul G Allen 104 Stinson |
Direct Write |
Profilometer Alphastep 500 alphastep |
Alphastep 500 Profilometer Training |
Flexible |
SNF Exfab Paul G Allen 104 Stinson |
500Å to 300µm |
PlasmaTherm Shuttlelock PECVD System ccp-dep |
PlasmaTherm Shuttlelock PECVD System Training |
"All" |
SNF Paul G Allen L107 Cleanroom |
To maintain cleanliness level, cleans of both the chamber and wafers are required prior to processing -
Substrates in clean category: Pre-Diffusion Clean
For semi-clean substrates: Standard Metal Clean (SRS100 + PRS1000) . Run Chamber clean (no dummies) and conditioning with clean dummies prior to run |
Wet Bench Flexible Solvents wbflexsolv |
Wet Bench Flexible Solvents 1 and 2 Training |
Flexible |
SNF Paul G Allen L107 Cleanroom |
Manual solvent cleaning of substrates or resist removal. |
SPTS uetch vapor etch uetch |
SPTS uetch vapor etch Training |
"All" |
SNF Paul G Allen L107 Cleanroom |
Pieces need a carrier wafer; Isotropic Etching |
Flexus 2320 Stress Tester stresstest |
Stress Tester Flexus 2320 Training |
"All" |
SNF Paul G Allen L107 Cleanroom |
|
Lesker2 Sputter lesker2-sputter |
Sputter Lesker 1&2 Training |
Semiclean |
SNF Paul G Allen L107 Cleanroom |
reactive O2/N2 sputtering, substrate bias, substrate heating, co-sputter |
Tystar Bank 2 Tube 8 LTO B2T8 Clean LTO |
Tystar LPCVD Tube Training |
Clean |
SNF Paul G Allen L107 Cleanroom |
|
PlasmaTherm Versaline HDP CVD System hdpcvd |
PlasmaTherm Versaline HDP CVD System Training |
"All" |
SNF Paul G Allen L107 Cleanroom |
To maintain cleanliness level there are cleans required for both the chamber and wafers prior to processing -
Substrates in clean category: Pre-Diffusion Clean
For semi-clean substrates: Standard Metal Clean (SRS100 + PRS1000) . Run Chamber clean (no dummies) and conditioning with clean dummies prior to run |
Critical Point Dryer Tousimis Automegasamdri-936 cpd |
Critical Point Dryer Training |
Flexible |
SNF Paul G Allen L107 Cleanroom |
CO2 drying after release of micromachined devices |
HMDS Vapor Prime Oven, YES yes |
YES Prime Oven Training |
"All" |
SNF Paul G Allen L107 Cleanroom |
Two programs: Singe and HMDS prime or Singe only. No Resist allowed! |
AJA2 Evaporator aja2-evap |
Evaporator AJA2 Training |
Flexible |
SNF Paul G Allen L107 Cleanroom |
For more than 300nm deposition, please contact Gabe Catalano <gcatalano@stanford.edu> in advance |