Skip to content Skip to navigation

Gallium Arsenide

Chemical Formula: 
GaAs
Subscribe to
Equipment name & NEMO ID Training Required & Charges Cleanliness Locationsort descending Notes
Keyence Digital Microscope VHX-6000
keyence
Microscope Keyence Training "All" SNF Exfab Paul G Allen 104 Stinson
SEM -Zeiss Merlin
sem-merlin
SEM-Merlin Training "All" SNF Exfab Paul G Allen 104 Stinson
Profilometer AlphaStep D-300
alphastep2
AlphaStep2 Training Flexible SNF Exfab Paul G Allen 104 Stinson
Nanospec 210XP
nanospec2
Nanospec Training "All" SNF Exfab Paul G Allen 104 Stinson

Manual Film Thickness Measurement. Single or dual layer transparent films > 300 Å

Profilometer Alphastep 500
alphastep
Alphastep 500 Profilometer Training Flexible SNF Exfab Paul G Allen 104 Stinson

500Å to 300µm

Heidelberg MLA 150
heidelberg
Heidelberg Training "All" SNF Exfab Paul G Allen 104 Stinson

Direct Write

Woollam
woollam
Woollam Training "All" SNF Paul G Allen L107 Cleanroom
HMDS Vapor Prime Oven, YES
yes
YES Prime Oven Training "All" SNF Paul G Allen L107 Cleanroom

Two programs: Singe and HMDS prime or Singe only. No Resist allowed!

Heidelberg MLA 150 - 2
heidelberg2
Heidelberg Training "All" SNF Paul G Allen L107 Cleanroom

Direct Write

Oven (White)
white-oven
White Oven Training Flexible SNF Paul G Allen L107 Cleanroom

For LOL2000 bake or bakes which are not allowed in the other ovens and need higher temperatures, up to 200C, programmable.

Headway Manual Resist Spinner
headway2
Resist Coat (manual) Headway Manual Training "All" SNF Paul G Allen L107 Cleanroom

Adjustable spin speeds, spin time. SNF-acceptable resists or polymers. Ebeam resists

Oven BlueM 200°C to 430°C
bluem
Blue M Oven Training Flexible SNF Paul G Allen L107 Cleanroom

Convection in N2. Cure. Programmable.

Samco PC300 Plasma Etch System
samco
Samco Training Flexible SNF Paul G Allen L107 Cleanroom
Oven 110°C post-bake
oven110
Resist Postbake Oven 110°C Training "All" SNF Paul G Allen L107 Cleanroom

Bakes wafers with resist after the development, called post-bake.

Lesker2 Sputter
lesker2-sputter
Sputter Lesker 1&2 Training Semiclean SNF Paul G Allen L107 Cleanroom

reactive O2/N2 sputtering, substrate bias, substrate heating, co-sputter

Wet Bench Flexcorr 1
wbflexcorr-1
Wet Bench Flexcorr 1and2 and 3and4 Training Flexible SNF Paul G Allen L107 Cleanroom

Manual wet etching of non-standard materials. Hot plate available. GaAs allowed in personal labware only.

Oven 90°C prebake
oven90
Resist Prebake Oven 90°C Training "All" SNF Paul G Allen L107 Cleanroom

Bakes wafers after resist coating.

Wet Bench Flexcorr 2
wbflexcorr-2
Wet Bench Flexcorr 1and2 and 3and4 Training Flexible SNF Paul G Allen L107 Cleanroom

Manual wet etching of non-standard materials. Hot pots available. GaAs allowed in personal labware only

Karl Suss MA-6 Contact Aligner
karlsuss2
Contact Aligner Karl Suss MA-6 Training "All" SNF Paul G Allen L107 Cleanroom

1:1 Contact Aligner.
Backside align.

Wet Bench Miscellaneous
wbmiscres
Wet Bench Miscellaneous Photoresist Training Flexible SNF Paul G Allen L107 Cleanroom

Manual development of resist in beakers and Headway (manual resist spinner). SNF approved developers (acid or base). No solvents!

Pages

Equipment name & NEMO ID Technique Cleaning Required Cleanliness Material Thickness Range Materials Lab Supplied Materials User Supplied Minimum Resolution Exposure Wavelength Mask Size Max Exposure Area Resist Process Temperature Range Chemicals Gases Sample Size Limits Resolution Notes Substrate Size Substrate Type Maximum Load
Aixtron MOCVD - III-V system
aix200
Pre-Diffusion Clean Flexible
0.00 - 5.00 μm
300 °C - 800 °C
,
,
,
,
,
4"x1 wafer or 2"x1 wafer or 4 pieces
AJA Evaporator
aja-evap
Flexible
0.00 - 300.00 nm
,
,
,
,
,
,
,
,
,
,
,
4"x3 or 6"x1 wafers or pieces
Critical Point Dryer Tousimis Automegasamdri-936
cpd
Flexible
,
,
,
,
,
,
,
,
,
Flexus 2320 Stress Tester
stresstest
"All" ,
,
,
,
,
,
,
,
1
Headway Manual Resist Spinner
headway2
"All" ,
,
,
,
,
,
,
,
,
one piece or wafer
Heidelberg MLA 150
heidelberg
"All"
405 nm ,
,
,
,
,
,
,
,
,
,
,
,
1
Heidelberg MLA 150 - 2
heidelberg2
"All"
375 nm ,
,
,
,
,
,
,
,
,
,
,
,
1
HMDS Vapor Prime Oven, YES
yes
"All"
150 ºC
,
,
,
,
,
,
,
,
Karl Suss MA-6 Contact Aligner
karlsuss
"All"
365 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Karl Suss MA-6 Contact Aligner
karlsuss2
"All"
365 nm or 405 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Keyence Digital Microscope VHX-6000
keyence
"All" ,
,
,
,
,
,
,
,
Lakeshore Hall Measurement System
LakeshoreHall
"All"
100.00 μm - 1000.00 μm
-258 °C - 1000 °C
8 in wafer

Sensor Transducer Size is 14 mm diameter 

,
,
,
,
,
,
,
,
,
,
1 piece
LEI1500 Contactless Sheet Resistance Mapping
eddycurrent
"All" 8 in wafer

Sensor Transducer Size is 14 mm diameter 

,
,
,
,
,
,
,
,
,
,
,
1 wafer(2" to 8")
Lesker Sputter
lesker-sputter
Flexible ,
,
,
,
,
,
,
,
,
1 4 inch wafer, 1 6 inch wafer
Lesker2 Sputter
lesker2-sputter
Semiclean
1.00 μm
°C - 800 °C
,
,
,
,
,
,
,
,
,
one 4 inch wafer, one 6 inch wafer
micromanipulator6000 IV-CV probe station
micromanipulator6000
"All" ,
,
,
,
,
,
,
,
,
,
,
1x4" wafer
Nanospec 210XP
nanospec2
"All" ,
,
,
,
,
,
,
,
Oven (White)
white-oven
Flexible
0 °C - 200 °C
,
,
,
,
,
,
,
,
Oven 110°C post-bake
oven110
"All"
110 ºC
,
,
,
,
,
,
,
,
,
Oven 90°C prebake
oven90
"All"
90 ºC
,
,
,
,
,
,
,
,

Pages