Skip to content Skip to navigation

Glass

Chemical Formula: 
SiO2
Subscribe to
Equipment name & NEMO ID Training Required & Charges Cleanliness Locationsort descending Notes
Finetech Lambda
flipchipbonder
Flip Chip Bonder Training Flexible SNF Exfab Paul G Allen 104 Stinson
SEM -Zeiss Merlin
sem-merlin
SEM-Merlin Training All SNF Exfab Paul G Allen 104 Stinson
Nanospec 210XP
nanospec2
Nanospec Training All SNF Exfab Paul G Allen 104 Stinson

Manual Film Thickness Measurement. Single or dual layer transparent films > 300 Å

Profilometer AlphaStep D-300
alphastep2
AlphaStep2 Training Flexible SNF Exfab Paul G Allen 104 Stinson
Keyence Digital Microscope VHX-6000
keyence
Microscope Keyence Training All SNF Exfab Paul G Allen 104 Stinson
Profilometer Alphastep 500
alphastep
Alphastep 500 Profilometer Training Flexible SNF Exfab Paul G Allen 104 Stinson

500Å to 300µm

Heidelberg MLA 150
heidelberg
Heidelberg Training All SNF Exfab Paul G Allen 104 Stinson

Direct Write

Fiji 2 ALD
fiji2
ALD Fiji 1 and 2 Training Flexible SNF Cleanroom Paul G Allen L107
Critical Point Dryer Tousimis Automegasamdri-915B
cpd
Critical Point Dryer Training Flexible SNF Cleanroom Paul G Allen L107

CO2 drying after release of micromachined devices

EVG Contact Aligner
evalign
Contact Aligner EVG Training All SNF Cleanroom Paul G Allen L107

1:1 Contact Aligner.
Anodic Bond, backside align, including IR.

Samco PC300 Plasma Etch System
samco
Samco Training Flexible SNF Cleanroom Paul G Allen L107
Savannah ALD
savannah
ALD Savannah Training Flexible SNF Cleanroom Paul G Allen L107
Matrix Plasma Resist Strip
matrix
Matrix Plasma Resist Strip Training Flexible SNF Cleanroom Paul G Allen L107

Single wafer tool with auto loading from a cassette. Pieces need a pocket carrier wafer for transport. Chuck temperature controls wafer heating.

Lesker2 Sputter
lesker2-sputter
Sputter Lesker 1&2 Training Semiclean SNF Cleanroom Paul G Allen L107

reactive O2/N2 sputtering, substrate bias, substrate heating, co-sputter

Woollam
woollam
Woollam Training All SNF Cleanroom Paul G Allen L107
Xactix Xenon Difluoride Etcher
xactix
Xactix Xenon Difluoride Etcher Training All SNF Cleanroom Paul G Allen L107

Isotropic Si etching; can be used for backside Si removal on small pieces

EVG Wafer Bonder
evbond
Wafer Bonder EVG Training Flexible SNF Cleanroom Paul G Allen L107
Oxford Dielectric Etcher
oxford-rie
Oxford Dielectric Etcher Training Flexible SNF Cleanroom Paul G Allen L107

4" wafers; can be adopted to do 6" or 8" wafers; pieces need to be bonded to carrier wafers

Headway Manual Resist Spinner
headway2
Resist Coat (manual) Headway Manual Training All SNF Cleanroom Paul G Allen L107

Adjustable spin speeds, spin time. SNF-acceptable resists or polymers. Ebeam resists

SVG Develop Track 1
svgdev
SVG Resist Develop tracks 1 and 2 Training All SNF Cleanroom Paul G Allen L107

Automatic development.

Pages

Equipment name & NEMO ID Technique Cleanliness Material Thickness Range Materials Lab Supplied Materials User Supplied Minimum Resolution Exposure Wavelength Mask Size Max Exposure Area Resist Process Temperature Range Chemicals Gases Sample Size Limits Resolution Notes Substrate Size Substrate Type Maximum Load
AJA Evaporator
aja-evap
Flexible
0.00 - 300.00 nm
,
,
,
,
,
,
,
,
,
,
,
4"x3 or 6"x1 wafers or pieces
ASML PAS 5500/60 i-line Stepper
asml
All
365 nm 5 inch
,
,
,
,
Critical Point Dryer Tousimis Automegasamdri-915B
cpd
Flexible
,
,
,
,
,
,
,
,
,
DISCO Wafer Saw
DISCO wafersaw
Flexible ,
,
,
,
,
,
,
,
1x4", 1x6" or 1x8" wafer, or pieces
EVG 101 Spray Coater
evgspraycoat
All ,
,
,
,
1
EVG Contact Aligner
evalign
All
350 - 450 nm 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch ,
,
,
,
one piece or wafer
EVG Wafer Bonder
evbond
Flexible ,
,
,
,
,
Fiji 2 ALD
fiji2
Flexible
1.00 Å - 50.00 nm
24 °C - 350 °C
,
,
,
,
,
,
,
,
,
,
,
,
Finetech Lambda
flipchipbonder
Flexible
°C - 400 °C
,
,
,
,
,
1
Flexus 2320 Stress Tester
stresstest
All ,
,
,
,
,
,
,
,
1
Headway Manual Resist Spinner
headway2
All ,
,
,
,
,
,
,
,
,
one piece or wafer
Heidelberg MLA 150
heidelberg
All
405 nm ,
,
,
,
,
,
,
,
,
,
,
,
1
Heidelberg MLA 150 - 2
heidelberg2
All
375 nm ,
,
,
,
,
,
,
,
,
,
,
,
1
HMDS Vapor Prime Oven, YES
yes
All
150 ºC
,
,
,
,
,
,
,
,
Karl Suss MA-6 Contact Aligner
karlsuss
All
365 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Karl Suss MA-6 Contact Aligner
karlsuss2
All
365 nm or 405 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Keyence Digital Microscope VHX-6000
keyence
All ,
,
,
,
,
,
,
,
Lakeshore Hall Measurement System
LakeshoreHall
All
100.00 μm - 1000.00 μm
-258 °C - 1000 °C
8 in wafer

Sensor Transducer Size is 14 mm diameter 

,
,
,
,
,
,
,
,
,
,
1 piece
LEI1500 Contactless Sheet Resistance Mapping
eddycurrent
All 8 in wafer

Sensor Transducer Size is 14 mm diameter 

,
,
,
,
,
,
,
,
,
,
,
1 wafer(2" to 8")
Lesker Sputter
lesker-sputter
Flexible ,
,
,
,
,
,
,
,
,
1 4 inch wafer, 1 6 inch wafer

Pages