Equipment name & NEMO ID Training Required & Charges Cleanliness Location Notes
Karl Suss MA-6 Contact Aligner
karlsuss2
Contact Aligner Karl Suss MA-6 Training All SNF Cleanroom Paul G Allen L107

1:1 Contact Aligner.
Backside align.

Keyence Digital Microscope VHX-6000
keyence
Microscope Keyence Training All SNF Exfab Paul G Allen 104 Stinson
Lakeshore Hall Measurement System
LakeshoreHall
Lakeshore Hall Measurement System training All SNF Exfab Paul G Allen 151 Ocean
LEI1500 Contactless Sheet Resistance Mapping
eddycurrent
LEI1500 Contactless Sheet Resistance Mapping Training All SNF Exfab Paul G Allen 151 Ocean
Lesker Sputter
lesker-sputter
Sputter Lesker 1&2 Training Flexible SNF Exfab Paul G Allen 155A Venice

reactive O2/N2 sputtering, substrate bias, substrate heating, co-sputter

Lesker2 Sputter
lesker2-sputter
Sputter Lesker 1&2 Training Semiclean SNF Cleanroom Paul G Allen L107

reactive O2/N2 sputtering, substrate bias, substrate heating, co-sputter

Matrix Plasma Resist Strip
matrix
Matrix Plasma Resist Strip Training Flexible SNF Cleanroom Paul G Allen L107

Single wafer tool with auto loading from a cassette. Pieces need a pocket carrier wafer for transport. Chuck temperature controls wafer heating.

micromanipulator6000 IV-CV probe station
micromanipulator6000
micromanipulator6000 IV-CV probe station Training All SNF Exfab Paul G Allen 151 Ocean
Nanospec 210XP
nanospec2
Nanospec Training All SNF Exfab Paul G Allen 104 Stinson

Manual Film Thickness Measurement. Single or dual layer transparent films > 300 Å

Oven (White)
white-oven
White Oven Training Flexible SNF Cleanroom Paul G Allen L107

For LOL2000 bake or bakes which are not allowed in the other ovens and need higher temperatures, up to 200C, programmable.

Oven 110°C post-bake
oven110
Resist Postbake Oven 110°C Training All SNF Cleanroom Paul G Allen L107

Bakes wafers with resist after the development, called post-bake.

Oven 90°C prebake
oven90
Resist Prebake Oven 90°C Training All SNF Cleanroom Paul G Allen L107

Bakes wafers after resist coating.

Oven BlueM 200°C to 430°C
bluem
Blue M Oven Training Flexible SNF Cleanroom Paul G Allen L107

Convection in N2. Cure. Programmable.

Oxford Dielectric Etcher
oxford-rie
Oxford Dielectric Etcher Training Flexible SNF Cleanroom Paul G Allen L107

4" wafers; can be adopted to do 6" or 8" wafers; pieces need to be bonded to carrier wafers

Oxford Plasma Pro ICP-RIE
Ox-gen
Ox-gen etcher Training Clean SNF Cleanroom Paul G Allen L107
PDS 2010 LABCOTER™ 2 Parylene Deposition System
parcoater
Parylene Coater Training Flexible SNF Exfab Paul G Allen 155 Mavericks
PlasmaTherm Shuttlelock PECVD System
ccp-dep
PlasmaTherm Shuttlelock PECVD System Training All SNF Cleanroom Paul G Allen L107

To maintain cleanliness level, cleans of both the chamber and wafers are required prior to processing -

Substrates in clean category: Pre-Diffusion Clean

For semi-clean substrates: Standard Metal Clean (SRS100 + PRS1000) . Run Chamber clean (no dummies) and conditioning with clean dummies prior to run

Profilometer Alphastep 500
alphastep
Alphastep 500 Profilometer Training Flexible SNF Exfab Paul G Allen 104 Stinson

500Å to 300µm

Profilometer AlphaStep D-300
alphastep2
AlphaStep2 Training Flexible SNF Exfab Paul G Allen 104 Stinson
Prometrix Resistivity Mapping System
prometrix
Prometrix Training All SNF Cleanroom Paul G Allen L107

3 Probe Heads for different cleanliness groups.

Pages

Equipment name & NEMO ID Technique Cleanliness Primary Materials Etched Other Materials Etched Material Thickness Range Materials Lab Supplied Materials User Supplied Minimum Resolution Exposure Wavelength Mask Size Max Exposure Area Process Temperature Range Gases Sample Size Limits Resolution Notes Substrate Size Substrate Type Maximum Load
Karl Suss MA-6 Contact Aligner
karlsuss2
All
365 nm or 405 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Keyence Digital Microscope VHX-6000
keyence
All ,
,
,
,
,
,
,
,
Lakeshore Hall Measurement System
LakeshoreHall
All
100.00 μm - 1000.00 μm
-258 °C - 1000 °C
8 in wafer

Sensor Transducer Size is 14 mm diameter 

,
,
,
,
,
,
,
,
,
,
1 piece
LEI1500 Contactless Sheet Resistance Mapping
eddycurrent
All 8 in wafer

Sensor Transducer Size is 14 mm diameter 

,
,
,
,
,
,
,
,
,
,
,
1 wafer(2" to 8")
Lesker Sputter
lesker-sputter
Flexible ,
,
,
,
,
,
,
,
,
1 4 inch wafer, 1 6 inch wafer
Lesker2 Sputter
lesker2-sputter
Semiclean
1.00 μm
°C - 800 °C
,
,
,
,
,
,
,
,
,
one 4 inch wafer, one 6 inch wafer
Matrix Plasma Resist Strip
matrix
Flexible
,
,
,
,
25
micromanipulator6000 IV-CV probe station
micromanipulator6000
All ,
,
,
,
,
,
,
,
,
,
,
1x4" wafer
Nanospec 210XP
nanospec2
All ,
,
,
,
,
,
,
,
Oven (White)
white-oven
Flexible
0 °C - 200 °C
,
,
,
,
,
,
,
,
Oven 110°C post-bake
oven110
All
110 ºC
,
,
,
,
,
,
,
,
,
Oven 90°C prebake
oven90
All
90 ºC
,
,
,
,
,
,
,
,
Oven BlueM 200°C to 430°C
bluem
Flexible
0 °C - 430 °C
,
,
,
,
,
,
,
,
,
Oxford Dielectric Etcher
oxford-rie
Flexible
,
,
,
,
1
Oxford Plasma Pro ICP-RIE
Ox-gen
Clean
-10 °C - 60 °C
,
,
1
PDS 2010 LABCOTER™ 2 Parylene Deposition System
parcoater
Flexible ,
,
,
,
,
,
,
,
,
,
,
,
PlasmaTherm Shuttlelock PECVD System
ccp-dep
All
100.00 Å - 4.00 μm
100 °C - 350 °C
,
,
,
,
,
,
,
,
4
Profilometer Alphastep 500
alphastep
Flexible ,
,
,
,
,
,
,
,
1
Profilometer AlphaStep D-300
alphastep2
Flexible ,
,
,
,
,
,
,
,
,
,
,
,
1
Prometrix Resistivity Mapping System
prometrix
All ,
,
,
,
,
,
,
,
1

Pages