Decontamination cleans are used to remove trace metals and particles from substrates. This step is required for post processing of wafers and pieces that have gone through KOH-etching, chemical-mechanical polishing (cmp), and the wafer saw. For more about the contamination categories, please visit the Cleanliness (previously Contamination) Groups page.

Processing Techniques Equipment name & NEMO ID Teaser Blurb Cleanliness Location
Decontamination, Wet Chemical Processing Wet Bench Decontamination
wbdecon

Decontamination of  3" or 4" silicon, quartz, or silicon germanium wafers after KOH, wafersaw, or cmp using SC2 before being allowed back into the clean equipment group.

Clean SNF Paul G Allen L107 Cleanroom
Decontamination, Metal Clean, Piranha Cleaning, Wet Resist Removal, Acid or Base Wet Etching, Aluminum and Titanium and Tungsten Wet Etching, Silicon Wet Etching, Silicon Oxide Wet Etching, Wet Chemical Processing Wet Bench Flexcorr 1
wbflexcorr-1

Manual wet etching of non-standard materials using only SNF approved acids or bases. Hot plate available. GaAs allowed in personal labware only.

Flexible SNF Paul G Allen L107 Cleanroom