Skip to content Skip to navigation

4 inch wafer

Short Name: 
4"

The following is a list of equipment where 4 inch round substrates are allowed.

Subscribe to
Equipment name & NEMO IDsort ascending Training Required & Charges Cleanliness Location Notes
Oven 110°C post-bake
oven110
Resist Postbake Oven 110°C Training All SNF Cleanroom Paul G Allen L107

Bakes wafers with resist after the development, called post-bake.

Oven (White)
white-oven
White Oven Training Flexible SNF Cleanroom Paul G Allen L107

For LOL2000 bake or bakes which are not allowed in the other ovens and need higher temperatures, up to 200C, programmable.

Optomec Printer
optomec-printer
Optomec Printer Training Flexible SNF Exfab Paul G Allen 155A Venice
Nanospec 3
nanospec3
Nanospec 3 Training All SNF Cleanroom Paul G Allen L107
Nanospec 210XP
nanospec2
Nanospec Training All SNF Exfab Paul G Allen 104 Stinson

Manual Film Thickness Measurement. Single or dual layer transparent films > 300 Å

MVD
mvd
MVD Training Flexible SNF Cleanroom Paul G Allen L107

Reactor located inside glovebox

MRC Reactive Ion Etcher
mrc
MRC Reactive Ion Etcher Training Flexible SNF Cleanroom Paul G Allen L107

Typically used for sputter etching; Single wafer, direct load system; wafers/ pieces can be directly placed on electrode

micromanipulator6000 IV-CV probe station
micromanipulator6000
micromanipulator6000 IV-CV probe station Training All SNF Exfab Paul G Allen 151 Ocean
Matrix Plasma Resist Strip
matrix
Matrix Plasma Resist Strip Training Flexible SNF Cleanroom Paul G Allen L107

Single wafer tool with auto loading from a cassette. Pieces need a pocket carrier wafer for transport. Chuck temperature controls wafer heating.

Lesker2 Sputter
lesker2-sputter
Sputter Lesker 1&2 Training Semiclean SNF Cleanroom Paul G Allen L107

reactive O2/N2 sputtering, substrate bias, substrate heating, co-sputter

Lesker Sputter
lesker-sputter
Sputter Lesker 1&2 Training Flexible SNF Exfab Paul G Allen 155A Venice

reactive O2/N2 sputtering, substrate bias, substrate heating, co-sputter

LEI1500 Contactless Sheet Resistance Mapping
eddycurrent
LEI1500 Contactless Sheet Resistance Mapping Training All SNF Exfab Paul G Allen 151 Ocean
Laurell Manual Resist Spinner
laurell-R
Laurell Manual Resist Spinner Training All SNF Cleanroom Paul G Allen L107

SU-8, LOL, Ebeam resists allowed. No Acetone allowed. 

Lam Research TCP 9400 Poly Etcher
lampoly
Lam Research TCP 9400 Poly Etcher Training Clean, Semiclean SNF Cleanroom Paul G Allen L107

Single wafer etch with auto-loading from a cassette. Equipment originally used for gate etching with high selectivity to thin gate oxides.

Keyence Digital Microscope VHX-6000
keyence
Microscope Keyence Training All SNF Exfab Paul G Allen 104 Stinson
Karl Suss MA-6 Contact Aligner
karlsuss2
Contact Aligner Karl Suss MA-6 Training All SNF Cleanroom Paul G Allen L107

1:1 Contact Aligner.
Backside align.

Karl Suss MA-6 Contact Aligner
karlsuss
Contact Aligner Karl Suss MA-6 Training All SNF Cleanroom Paul G Allen L107

1:1 Contact Aligner.
Backside align, including IR.

Intlvac Evaporator
Intlvac_evap
Evaporator Intlvac Training Clean, Semiclean SNF Cleanroom Paul G Allen L107
HMDS Vapor Prime Oven, YES
yes
YES Prime Oven Training All SNF Cleanroom Paul G Allen L107

Two programs: Singe and HMDS prime or Singe only. No Resist allowed!

Heidelberg MLA 150 - 2
heidelberg2
Heidelberg Training All SNF Cleanroom Paul G Allen L107

Direct Write

Pages

Equipment name & NEMO IDsort ascending Technique Cleanliness Primary Materials Etched Other Materials Etched Material Thickness Range Materials Lab Supplied Materials User Supplied Minimum Resolution Exposure Wavelength Mask Size Max Exposure Area Resist Process Temperature Range Chemicals Gases Sample Size Limits Resolution Notes Substrate Size Substrate Type Maximum Load
Oven 110°C post-bake
oven110
All
110 ºC
,
,
,
,
,
,
,
,
,
Oven (White)
white-oven
Flexible
0 °C - 200 °C
,
,
,
,
,
,
,
,
Optomec Printer
optomec-printer
Flexible
Nanospec 3
nanospec3
All
Nanospec 210XP
nanospec2
All ,
,
,
,
,
,
,
,
MVD
mvd
Flexible
1.00 Å - 50.00 nm
24 °C - 150 °C
MRC Reactive Ion Etcher
mrc
Flexible 1
micromanipulator6000 IV-CV probe station
micromanipulator6000
All ,
,
,
,
,
,
,
,
,
,
,
1x4" wafer
Matrix Plasma Resist Strip
matrix
Flexible
,
,
,
,
25
Lesker2 Sputter
lesker2-sputter
Semiclean
1.00 μm
°C - 800 °C
,
,
,
,
,
,
,
,
,
one 4 inch wafer, one 6 inch wafer
Lesker Sputter
lesker-sputter
Flexible ,
,
,
,
,
,
,
,
,
1 4 inch wafer, 1 6 inch wafer
LEI1500 Contactless Sheet Resistance Mapping
eddycurrent
All 8 in wafer

Sensor Transducer Size is 14 mm diameter 

,
,
,
,
,
,
,
,
,
,
,
1 wafer(2" to 8")
Laurell Manual Resist Spinner
laurell-R
All
Lam Research TCP 9400 Poly Etcher
lampoly
Clean, Semiclean
,
25
Keyence Digital Microscope VHX-6000
keyence
All ,
,
,
,
,
,
,
,
Karl Suss MA-6 Contact Aligner
karlsuss2
All
365 nm or 405 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Karl Suss MA-6 Contact Aligner
karlsuss
All
365 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Intlvac Evaporator
Intlvac_evap
Clean, Semiclean
0.00 - 0.50 μm
,
,
12 4 inch wafers, 2 6 inch wafers
HMDS Vapor Prime Oven, YES
yes
All
150 ºC
,
,
,
,
,
,
,
,
Heidelberg MLA 150 - 2
heidelberg2
All
375 nm ,
,
,
,
,
,
,
,
,
,
,
,
1

Pages