Skip to content Skip to navigation

4 inch wafer

Short Name: 
4"

The following is a list of equipment where 4 inch round substrates are allowed.

Subscribe to
Equipment name & NEMO ID Training Required & Charges Cleanliness Locationsort ascending Notes
EVG Wafer Bonder
evbond
Wafer Bonder EVG Training Flexible SNF Cleanroom Paul G Allen L107
Tystar Bank 1 Tube 3 Poly
B1T3 Flexible Poly
Tystar LPCVD Tube Training Flexible SNF Cleanroom Paul G Allen L107
Wet Bench Clean_res-piranha
wbclean_res-piranha
Wet Bench Clean Piranha/HF/Phosphoric Training Clean SNF Cleanroom Paul G Allen L107

Resist will be removed

EVG 101 Spray Coater
evgspraycoat
Spray Coater EVG 101 Training All SNF Cleanroom Paul G Allen L107

Spray coating of resists

Tystar Bank 3 Tube 12 Poly
B3T12 Clean Poly
Tystar LPCVD Tube Training Clean SNF Cleanroom Paul G Allen L107
AMAT Centurion Epitaxial System
epi2
Epitaxial AMAT Centurion Training Clean SNF Cleanroom Paul G Allen L107

N and P doping available- intrinsic to 5E19 Operating pressure range is 5-300Torr

Wet Bench Flexcorr 3
wbflexcorr-3
Wet Bench Flexcorr 1and2 and 3and4 Training Flexible SNF Cleanroom Paul G Allen L107

Manual wet etching of non-standard materials using acids or bases. Hot Plate available. GaAs not allowed.

SVG Resist Coat Track 1
svgcoat
SVG Resist Coat Tracks 1 and 2 Training All SNF Cleanroom Paul G Allen L107

Automatic Resist spinning and bake

Sensofar S-neox
s-neox
Sensofar S-neox Training All SNF Cleanroom Paul G Allen L107

non contact 3D optical profiling

Tystar Bank 3 Tube 10 Nitride
B3T10 Clean Nitride
Tystar LPCVD Tube Training Clean SNF Cleanroom Paul G Allen L107
PlasmaTherm Shuttlelock PECVD System
ccp-dep
PlasmaTherm Shuttlelock PECVD System Training All SNF Cleanroom Paul G Allen L107

To maintain cleanliness level, cleans of both the chamber and wafers are required prior to processing -

Substrates in clean category: Pre-Diffusion Clean

For semi-clean substrates: Standard Metal Clean (SRS100 + PRS1000) . Run Chamber clean (no dummies) and conditioning with clean dummies prior to run

Wet Bench Flexible Solvents
wbflexsolv
Wet Bench Flexible Solvents 1 and 2 Training Flexible SNF Cleanroom Paul G Allen L107

Manual solvent cleaning of substrates or resist removal.

SPTS uetch vapor etch
uetch
SPTS uetch vapor etch Training All SNF Cleanroom Paul G Allen L107

Pieces need a carrier wafer; Isotropic Etching

Tencor P2 Profilometer
p2
Tencor P2 Profilometer Training Clean, Semiclean SNF Cleanroom Paul G Allen L107

Step height measurement range 500 Å to 80 µm

Heidelberg MLA 150 - 2
heidelberg2
Heidelberg Training All SNF Cleanroom Paul G Allen L107

Direct Write

Tystar Bank 2 Tube 7 Nitride
B2T7 Clean Nitride
Tystar LPCVD Tube Training Clean SNF Cleanroom Paul G Allen L107
PlasmaTherm Versaline HDP CVD System
hdpcvd
PlasmaTherm Versaline HDP CVD System Training All SNF Cleanroom Paul G Allen L107

To maintain cleanliness level there are cleans required for both the chamber and wafers prior to processing -

Substrates in clean category: Pre-Diffusion Clean

For semi-clean substrates: Standard Metal Clean (SRS100 + PRS1000) .  Run Chamber clean (no dummies) and conditioning with clean dummies prior to run

Critical Point Dryer Tousimis Automegasamdri-915B
cpd
Critical Point Dryer Training Flexible SNF Cleanroom Paul G Allen L107

CO2 drying after release of micromachined devices

HMDS Vapor Prime Oven, YES
yes
YES Prime Oven Training All SNF Cleanroom Paul G Allen L107

Two programs: Singe and HMDS prime or Singe only. No Resist allowed!

Technics Asher
technics
Technics Asher Training Flexible SNF Cleanroom Paul G Allen L107

Pages

Equipment name & NEMO ID Technique Cleanliness Primary Materials Etched Other Materials Etched Material Thickness Range Materials Lab Supplied Materials User Supplied Minimum Resolution Exposure Wavelength Mask Size Max Exposure Area Resist Process Temperature Range Chemicals Gases Sample Size Limits Resolution Notes Substrate Size Substrate Type Maximum Load
Gasonics Aura Asher
gasonics
Clean, Semiclean
25
Headway 3 Manual Resist Spinner
headway3
All 1 piece or wafer
Headway Manual Resist Spinner
headway2
All ,
,
,
,
,
,
,
,
,
one piece or wafer
Heidelberg MLA 150
heidelberg
All
405 nm ,
,
,
,
,
,
,
,
,
,
,
,
1
Heidelberg MLA 150 - 2
heidelberg2
All
375 nm ,
,
,
,
,
,
,
,
,
,
,
,
1
HMDS Vapor Prime Oven, YES
yes
All
150 ºC
,
,
,
,
,
,
,
,
Intlvac Evaporator
Intlvac_evap
Clean, Semiclean
0.00 - 0.50 μm
,
,
12 4 inch wafers, 2 6 inch wafers
Karl Suss MA-6 Contact Aligner
karlsuss
All
365 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Karl Suss MA-6 Contact Aligner
karlsuss2
All
365 nm or 405 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Keyence Digital Microscope VHX-6000
keyence
All ,
,
,
,
,
,
,
,
Lam Research TCP 9400 Poly Etcher
lampoly
Clean, Semiclean
,
25
Laurell Manual Resist Spinner
laurell-R
All
LEI1500 Contactless Sheet Resistance Mapping
eddycurrent
All 8 in wafer

Sensor Transducer Size is 14 mm diameter 

,
,
,
,
,
,
,
,
,
,
,
1 wafer(2" to 8")
Lesker Sputter
lesker-sputter
Flexible ,
,
,
,
,
,
,
,
,
1 4 inch wafer, 1 6 inch wafer
Lesker2 Sputter
lesker2-sputter
Semiclean
1.00 μm
°C - 800 °C
,
,
,
,
,
,
,
,
,
one 4 inch wafer, one 6 inch wafer
Matrix Plasma Resist Strip
matrix
Flexible
,
,
,
,
25
micromanipulator6000 IV-CV probe station
micromanipulator6000
All ,
,
,
,
,
,
,
,
,
,
,
1x4" wafer
MRC Reactive Ion Etcher
mrc
Flexible 1
MVD
mvd
Flexible
1.00 Å - 50.00 nm
24 °C - 150 °C
Nanospec 210XP
nanospec2
All ,
,
,
,
,
,
,
,

Pages