Keyence Digital Microscope VHX-6000 keyence |
Microscope Keyence Training |
"All" |
SNF Exfab Paul G Allen 104 Stinson |
|
Finetech Lambda flipchipbonder |
Flip Chip Bonder Training |
Flexible |
SNF Exfab Paul G Allen 104 Stinson |
|
Nanospec 210XP nanospec2 |
Nanospec Training |
"All" |
SNF Exfab Paul G Allen 104 Stinson |
Manual Film Thickness Measurement. Single or dual layer transparent films > 300 Ã
|
SEM -Zeiss Merlin sem-merlin |
SEM-Merlin Training |
"All" |
SNF Exfab Paul G Allen 104 Stinson |
|
Profilometer AlphaStep D-300 alphastep2 |
AlphaStep2 Training |
Flexible |
SNF Exfab Paul G Allen 104 Stinson |
|
Heidelberg MLA 150 heidelberg |
Heidelberg Training |
"All" |
SNF Exfab Paul G Allen 104 Stinson |
Direct Write |
Profilometer Alphastep 500 alphastep |
Alphastep 500 Profilometer Training |
Flexible |
SNF Exfab Paul G Allen 104 Stinson |
500Å to 300µm |
Wet Bench Flexcorr 3 wbflexcorr-3 |
Wet Bench Flexcorr 1and2 and 3and4 Training |
Flexible |
SNF Paul G Allen L107 Cleanroom |
Manual wet etching of non-standard materials using acids or bases. Hot Plate available. GaAs not allowed. |
Oven 90°C prebake oven90 |
Resist Prebake Oven 90°C Training |
"All" |
SNF Paul G Allen L107 Cleanroom |
Bakes wafers after resist coating. |
SVG Develop Track 2 svgdev2 |
SVG Resist Develop tracks 1 and 2 Training |
"All" |
SNF Paul G Allen L107 Cleanroom |
Automatic development. |
Tystar Bank 3 Tube 12 Poly B3T12 Clean Poly |
Tystar LPCVD Tube Training |
Clean |
SNF Paul G Allen L107 Cleanroom |
|
Headway Manual Resist Spinner headway2 |
Resist Coat (manual) Headway Manual Training |
"All" |
SNF Paul G Allen L107 Cleanroom |
Adjustable spin speeds, spin time. SNF-acceptable resists or polymers. Ebeam resists |
Wet Bench Flexible Solvents wbflexsolv |
Wet Bench Flexible Solvents 1 and 2 Training |
Flexible |
SNF Paul G Allen L107 Cleanroom |
Manual solvent cleaning of substrates or resist removal. |
Karl Suss MA-6 Contact Aligner karlsuss2 |
Contact Aligner Karl Suss MA-6 Training |
"All" |
SNF Paul G Allen L107 Cleanroom |
1:1 Contact Aligner.
Backside align. |
Tystar Bank 3 Tube 10 Nitride B3T10 Clean Nitride |
Tystar LPCVD Tube Training |
Clean |
SNF Paul G Allen L107 Cleanroom |
|
Critical Point Dryer Tousimis Automegasamdri-936 cpd |
Critical Point Dryer Training |
Flexible |
SNF Paul G Allen L107 Cleanroom |
CO2 drying after release of micromachined devices |
Karl Suss MA-6 Contact Aligner karlsuss |
Contact Aligner Karl Suss MA-6 Training |
"All" |
SNF Paul G Allen L107 Cleanroom |
1:1 Contact Aligner.
Backside align, including IR. |
Heidelberg MLA 150 - 2 heidelberg2 |
Heidelberg Training |
"All" |
SNF Paul G Allen L107 Cleanroom |
Direct Write |
Tystar Bank 2 Tube 7 Nitride B2T7 Flexible Nitride |
Tystar LPCVD Tube Training |
Flexible |
SNF Paul G Allen L107 Cleanroom |
|
PlasmaTherm Shuttlelock PECVD System ccp-dep |
PlasmaTherm Shuttlelock PECVD System Training |
"All" |
SNF Paul G Allen L107 Cleanroom |
To maintain cleanliness level, cleans of both the chamber and wafers are required prior to processing -
Substrates in clean category: Pre-Diffusion Clean
For semi-clean substrates: Standard Metal Clean (SRS100 + PRS1000) . Run Chamber clean (no dummies) and conditioning with clean dummies prior to run |