Subscribe to
Equipment name & NEMO ID Training Required & Charges Cleanliness Locationsort descending Notes
Wet Bench Clean 1
wbclean-1
Wet Bench Clean1and2 Training Clean SNF Paul G Allen L107 Cleanroom

No resist allowed. Resist should have been removed at the wbclean_res-piranha.

Oven (White)
white-oven
White Oven Training Flexible SNF Paul G Allen L107 Cleanroom

For LOL2000 bake or bakes which are not allowed in the other ovens and need higher temperatures, up to 200C, programmable.

Intlvac Evaporator
Intlvac_evap
Evaporator Intlvac Training Clean, Semiclean SNF Paul G Allen L107 Cleanroom
Oxford Plasma Pro ICP-RIE ALE
Ox-ALE
Oxford Plasma Pro ICP-RIE ALE Training Flexible SNF Paul G Allen L107 Cleanroom
Wet Bench Flexcorr 1
wbflexcorr-1
Wet Bench Flexcorr 1and2 and 3and4 Training Flexible SNF Paul G Allen L107 Cleanroom

Manual wet etching of non-standard materials. Hot plate available. GaAs allowed in personal labware only.

MRC Reactive Ion Etcher
mrc
MRC Reactive Ion Etcher Training Flexible SNF Paul G Allen L107 Cleanroom

Typically used for sputter etching; Single wafer, direct load system; wafers/ pieces can be directly placed on electrode

Oven BlueM 200°C to 430°C
bluem
Blue M Oven Training Flexible SNF Paul G Allen L107 Cleanroom

Convection in N2. Cure. Programmable.

SVG Resist Coat Track 2
svgcoat2
SVG Resist Coat Tracks 1 and 2 Training "All" SNF Paul G Allen L107 Cleanroom

Automatic HMDS, Resist spinning, and Bake. AZ5214IR Image Reversal.

Tystar Bank 1 Tube 2
B1T2 Flexible Oxide
Tystar Atmospheric Tube Training Flexible SNF Paul G Allen L107 Cleanroom
Wet Bench Flexcorr 2
wbflexcorr-2
Wet Bench Flexcorr 1and2 and 3and4 Training Flexible SNF Paul G Allen L107 Cleanroom

Manual wet etching of non-standard materials. Hot pots available. GaAs allowed in personal labware only

Gasonics Aura Asher
gasonics
Resist Removal Dry Gasonics Training Clean, Semiclean SNF Paul G Allen L107 Cleanroom

Single wafer tool with auto loading from a cassette. Pieces need a pocket carrier wafer for transport. Wafers heated by lamps.

Oven 110°C post-bake
oven110
Resist Postbake Oven 110°C Training "All" SNF Paul G Allen L107 Cleanroom

Bakes wafers with resist after the development, called post-bake.

Wet Bench Clean 2
wbclean-2
Wet Bench Clean1and2 Training Clean SNF Paul G Allen L107 Cleanroom

No resist allowed. Resist should have been removed at the wbclean_res-piranha

Tystar Bank 2 Tube 5
B2T5 Clean Anneal
Tystar Atmospheric Tube Training Clean SNF Paul G Allen L107 Cleanroom
Fiji 2 ALD
fiji2
ALD Fiji 1 and 2 Training Flexible SNF Paul G Allen L107 Cleanroom
Wet Bench CMOS Metal
wbclean3
Wet Bench CMOS Metal (wbclean3) Training Semiclean SNF Paul G Allen L107 Cleanroom

Al, Ti, or W wet etching or oxide etching

Plasma Therm Versaline LL ICP Metal Etcher
PT-MTL
Plasma Therm Versaline LL ICP Metal Etcher Training Flexible SNF Paul G Allen L107 Cleanroom

Single wafer; Default 4" config; Can be converted to 6" config; pieces need to be attached to carrier wafer; Restrictions: Can not etch metals or metal oxides with no volatile by-products (shorting & arcing issues)

Oven 90°C prebake
oven90
Resist Prebake Oven 90°C Training "All" SNF Paul G Allen L107 Cleanroom

Bakes wafers after resist coating.

SVG Develop Track 2
svgdev2
SVG Resist Develop tracks 1 and 2 Training "All" SNF Paul G Allen L107 Cleanroom

Automatic development.

Tystar Bank 2 Tube 6
B2T6 Clean Oxide
Tystar Atmospheric Tube Training Clean SNF Paul G Allen L107 Cleanroom

Pages

Equipment name & NEMO ID Technique Cleanliness Primary Materials Etched Other Materials Etched Material Thickness Range Materials Lab Supplied Materials User Supplied Minimum Resolution Exposure Wavelength Mask Size Max Exposure Area Resist Process Temperature Range Chemicals Gases Sample Size Limits Resolution Notes Substrate Size Substrate Type Maximum Load
Headway 3 Manual Resist Spinner
headway3
"All" 1 piece or wafer
Headway Manual Resist Spinner
headway2
"All" ,
,
,
,
,
,
,
,
,
one piece or wafer
Heidelberg MLA 150
heidelberg
"All"
405 nm ,
,
,
,
,
,
,
,
,
,
,
,
1
Heidelberg MLA 150 - 2
heidelberg2
"All"
375 nm ,
,
,
,
,
,
,
,
,
,
,
,
1
HMDS Vapor Prime Oven, YES
yes
"All"
150 ºC
,
,
,
,
,
,
,
,
Intlvac Evaporator
Intlvac_evap
Clean, Semiclean
0.00 - 0.50 μm
,
,
12 4 inch wafers, 2 6 inch wafers
Karl Suss MA-6 Contact Aligner
karlsuss
"All"
365 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Karl Suss MA-6 Contact Aligner
karlsuss2
"All"
365 nm or 405 nm 4 inch, 5 inch, 7 inch 5 inch mask = 4 inch, 7 inch mask = 6 inch, 4 inch mask = 3 inch ,
,
,
,
,
,
,
,
,
Keyence Digital Microscope VHX-6000
keyence
"All" ,
,
,
,
,
,
,
,
KJL Evaporator 1
200.00 nm
1
Lam Research TCP 9400 Poly Etcher
lampoly
Clean, Semiclean
,
25
Laurell Manual Resist Spinner
laurell-R
"All"
LEI1500 Contactless Sheet Resistance Mapping
eddycurrent
"All" 8 in wafer

Sensor Transducer Size is 14 mm diameter 

,
,
,
,
,
,
,
,
,
,
,
1 wafer(2" to 8")
Lesker Sputter
lesker-sputter
Flexible ,
,
,
,
,
,
,
,
,
1 4 inch wafer, 1 6 inch wafer
Lesker2 Sputter
lesker2-sputter
Semiclean
1.00 μm
°C - 800 °C
,
,
,
,
,
,
,
,
,
one 4 inch wafer, one 6 inch wafer
Matrix Plasma Resist Strip
matrix
Flexible
,
,
,
,
25
micromanipulator6000 IV-CV probe station
micromanipulator6000
"All" ,
,
,
,
,
,
,
,
,
,
,
1x4" wafer
MRC Reactive Ion Etcher
mrc
Flexible 1
MVD
mvd
Flexible
1.00 Å - 50.00 nm
24 °C - 150 °C
Nanospec 210XP
nanospec2
"All" ,
,
,
,
,
,
,
,

Pages