Skip to content Skip to navigation

2 inch wafer

Short Name: 
2"

The following is a list of equipment where 2 inch round substrates are allowed.

Subscribe to
Equipment name & NEMO IDsort descending Training Required & Charges Cleanliness Location Notes
Plasmaetch PE-50
plasma-etch
Plasmaetch PE-50 Training Flexible SNF Exfab Paul G Allen 155A Venice

Low power, high pressure plasma; low bias, minimal damage. Often used for surface treatment.

Profilometer Alphastep 500
alphastep
Alphastep 500 Profilometer Training Flexible SNF Exfab Paul G Allen 104 Stinson

500Å to 300µm

Profilometer AlphaStep D-300
alphastep2
AlphaStep2 Training Flexible SNF Exfab Paul G Allen 104 Stinson
Prometrix Resistivity Mapping System
prometrix
Prometrix Training "All" SNF Paul G Allen L107 Cleanroom

3 Probe Heads for different cleanliness groups.

RTA AllWin 610
aw610_r
AllWin 610 RTA Training Flexible SNF Paul G Allen L107 Cleanroom
RTA AllWin 610
aw610_l
AllWin 610 RTA Training Clean SNF Paul G Allen L107 Cleanroom
Samco PC300 Plasma Etch System
samco
Samco Training Flexible SNF Paul G Allen L107 Cleanroom
Savannah ALD
savannah
ALD Savannah Training Flexible SNF Paul G Allen L107 Cleanroom
SEM -Zeiss Merlin
sem-merlin
SEM-Merlin Training "All" SNF Exfab Paul G Allen 104 Stinson
Sensofar S-neox
s-neox
Sensofar S-neox Training "All" SNF Paul G Allen L107 Cleanroom

non contact 3D optical profiling

Sinton Lifetime Tester
sinton-lifetime-tester
Sinton Lifetime Tester Training Flexible SNF Exfab Paul G Allen 151 Ocean
SPTS uetch vapor etch
uetch
SPTS uetch vapor etch Training "All" SNF Paul G Allen L107 Cleanroom

Pieces need a carrier wafer; Isotropic Etching

Wet Bench Flexcorr 1
wbflexcorr-1
Wet Bench Flexcorr 1and2 and 3and4 Training Flexible SNF Paul G Allen L107 Cleanroom

Manual wet etching of non-standard materials. Hot plate available. GaAs allowed in personal labware only.

Wet Bench Flexcorr 2
wbflexcorr-2
Wet Bench Flexcorr 1and2 and 3and4 Training Flexible SNF Paul G Allen L107 Cleanroom

Manual wet etching of non-standard materials. Hot pots available. GaAs allowed in personal labware only

Wet Bench Flexcorr 3
wbflexcorr-3
Wet Bench Flexcorr 1and2 and 3and4 Training Flexible SNF Paul G Allen L107 Cleanroom

Manual wet etching of non-standard materials using acids or bases. Hot Plate available. GaAs not allowed.

Wet Bench Flexcorr 4
wbflexcorr-4
Wet Bench Flexcorr 1and2 and 3and4 Training Flexible SNF Paul G Allen L107 Cleanroom

Manual wet etching of non-standard materials using acids or bases. Hot plate, HF bath, and controlled temperature bath available. GaAs not allowed.

Wet Bench Flexible Solvents
wbflexsolv
Wet Bench Flexible Solvents 1 and 2 Training Flexible SNF Paul G Allen L107 Cleanroom

Manual solvent cleaning of substrates or resist removal.

Wet Bench Flexible Solvents 1
wbflexsolv-1
Wet Bench Flexible Solvents 1 and 2 Training Flexible SNF Paul G Allen L107 Cleanroom

Manual solvent cleaning, two ultrasonic baths.

Wet Bench Flexible Solvents 2
wbflexsolv-2
Wet Bench Flexible Solvents 1 and 2 Training Flexible SNF Paul G Allen L107 Cleanroom

Manual solvent cleaning, hot plate

Wet Bench Miscellaneous
wbmiscres
Wet Bench Miscellaneous Photoresist Training Flexible SNF Paul G Allen L107 Cleanroom

Manual development of resist in beakers and Headway (manual resist spinner). SNF approved developers (acid or base). No solvents!

Pages

Equipment name & NEMO IDsort descending Technique Cleaning Required Cleanliness Primary Materials Etched Other Materials Etched Material Thickness Range Materials Lab Supplied Developer Process Temperature Range Chemicals Gases Sample Size Limits Substrate Size Substrate Type Maximum Load
Plasmaetch PE-50
plasma-etch
Flexible Multiple
Profilometer Alphastep 500
alphastep
Flexible ,
,
,
,
,
,
,
,
1
Profilometer AlphaStep D-300
alphastep2
Flexible ,
,
,
,
,
,
,
,
,
,
,
,
1
Prometrix Resistivity Mapping System
prometrix
"All" ,
,
,
,
,
,
,
,
1
RTA AllWin 610
aw610_r
Flexible
21 °C - 1150 °C
,
,
RTA AllWin 610
aw610_l
Pre-Diffusion Clean Clean
21 °C - 1150 °C
,
,
1 wafer
Samco PC300 Plasma Etch System
samco
Flexible
20 ºC
,
,
,
,
,
,
,
,
,
,
,
,
,
Four 4" wafers or two 6" wafers and one 8" wafer
Savannah ALD
savannah
Flexible
1.00 Å - 50.00 nm
24 °C - 250 °C
,
,
,
,
,
,
,
,
,
,
,
,
SEM -Zeiss Merlin
sem-merlin
"All"
0.00 mm - 35.00 mm
6 in wafer ,
,
,
,
,
,
,
,
,
,
one
Sensofar S-neox
s-neox
"All" ,
,
,
,
,
,
,
,
1
Sinton Lifetime Tester
sinton-lifetime-tester
Flexible
SPTS uetch vapor etch
uetch
"All" ,
,
,
,
,
,
,
,
,
1
Wet Bench Flexcorr 1
wbflexcorr-1
Flexible ,
,
,
,
,
,
,
,
,
,
Wet Bench Flexcorr 2
wbflexcorr-2
Flexible ,
,
,
,
,
,
,
,
,
,
Wet Bench Flexcorr 3
wbflexcorr-3
Flexible ,
,
,
,
,
,
,
,
,
Wet Bench Flexcorr 4
wbflexcorr-4
Flexible
Wet Bench Flexible Solvents
wbflexsolv
Flexible ,
,
,
,
,
,
,
,
,
,
Wet Bench Flexible Solvents 1
wbflexsolv-1
Flexible ,
,
,
,
,
,
,
,
,
,
Wet Bench Flexible Solvents 2
wbflexsolv-2
Flexible ,
,
,
,
,
,
,
,
,
,
Wet Bench Miscellaneous
wbmiscres
Flexible ,
,
,
,
,
,
,
,

Pages